PHONE ORDERS: 0522943564 | WHATSAPP: 3497113669

FREE SHIPPING

For orders over €299.00

Globus  |  SKU: 0000008487

Globus Genesy 3000 electrostimulator

Globus Genesy 3000 is the most complete and advanced electrostimulator in the professional range.
It has 530 main programs for rehabilitation, pain, aesthetics, sports, including iontophoresis. 4 output channels, programmable, mains and battery powered.

€979,00 EUR €999,00
Tax included Shipping calculated at checkout.

Availability status: Available

Product Features:

The Globus Genesy 3000 represents the flagship of the new Globus professional range as it concentrates the best technologies and functions that Globus has developed in recent years.

This second-generation professional electrostimulator is in fact the result of a new hardware and software project that has implemented the potential for use in the medical, rehabilitation and physiotherapy fields.

The unit, characterised by larger dimensions and an ergonomic design, thanks to its mains and battery operation can be used both as a fixed station and as a portable unit.

The Genesy 3000 is the most equipped stimulator for the treatment of pain, to promote tissue healing and to treat neuromuscular dysfunctions.
The System is designed to allow a more effective and rapid re-athleticization of injured athletes and to reduce, at the same time, the possibility of new injuries. The programs are specifically designed both to resolve the acute post-traumatic phase and to recover athletes who should undergo reconstructive surgery.

This machine also has a set of specific programs for athletic preparation in the most important sports disciplines.
The facilities are completed by a full range of body care treatments with purely aesthetic purposes.

8 DIFFERENT TYPES OF CURRENT

The Genesy 3000 in particular stands out for its ability to deliver all the main medical currents:


-EMS currents (Electro Muscle Stimulation)
-TENS currents (Trans Cutaneus Nerve Stimulation)
-MENS currents (Micro Current Stimulation)
-Kotz currents with sine wave
-Interferential Currents
-Triangular and Trapezoidal wave currents for the Denervated M.
-Direct Current for Ionophoresis

9 APPLICATION AREAS

The technologies used are the most advanced and allow for extremely easy and safe use of the stimulator in any therapeutic situation.


-Functional re-education (EMS and MENS),
-Pain Therapy (TENS and MENS),
-Endorphin Pain Therapy (TENS and MENS)
-Diagnosis and Treatment of Denervated Muscle Paralysis
-Rehabilitation treatments (Kotz and Interferential)
-Deep Pharmacological Treatment (Ionophoresis)
-High Level Sports Training (EMS)
-Fitness Preparation (EMS)
-Aesthetic Treatments (EMS, MENS).

STRENGTHS

Considerable attention has been paid to making the use of the machine more intuitive and user-friendly.

GENESY SERIES FUNCTIONS


EASY PROGRAM: allows for faster programming
MY TRAINER: view all the images of the electrode placement directly on the display
STIM FIT: allows you to modify the contraction parameters during stimulation
FAST MENU: makes navigation faster
STIM LOCK: allows the therapist to have the patient use only the programs that have been prescribed to him
WORK TIME: displays the actual machine usage times by all users
MAINS & BATTERY OPERATION.
NEW DOUBLE POWER BATTERY

SPECIAL FUNCTIONS


BACKLIT GRAPHIC DISPLAY
DUAL STIM 2+2: possibility of running two different programs at the same time.
AUTO STIM: the only electrostimulator that allows you to run a program automatically without having to manually adjust the intensity.
SYNCROSTIM: By pressing a single button, you can increase the intensity of the 4 channels simultaneously.
MULTI-USER: allows you to share the stimulator between multiple users, keeping their respective settings, preferences and programs memorized.
MEMO FUNCTION: allows you to create a library of customized programs.
LAST 10: stores the last programs performed. In this way they are available for quick and easy execution.

PROGRAMS

Rehab

Rehabilitation programs use EMS currents to restore normal muscle efficiency in post-injury recovery treatments.
Muscle stimulation is also a useful tool in some situations where normal neuromuscular function is compromised.

Atrophy Recovery, Point Finder, Muscle Building, Strengthening, Mobilization, Agonist/Antagonist, Cruciate Ligament Stretching, Achilles Tendon Stretching, Upper Ligament Ligament Stretching, Upper Limb Hemiplegia, Lower Limb Hemiplegia, Bladder Instability, Mixed Incontinence, Stress Incontinence, Paraplegia (injury prevention), Upper Limb Spasticity, Lower Limb Spasticity, Hip Prosthesis
Tens

Transcutaneous Electrical Nerve Stimulation. Transcutaneous electrical nerve stimulation (TENS) is a pain-relieving stimulation that is performed with impulses that reach the peripheral nervous system through electrodes positioned on the area to be treated. TENS stimulation is performed with symmetrical biphasic impulses and with frequencies that can vary from 8 to 200 Hz.

Endorphinic Tens, Hematomas, Contractures, Sciatica, Anti-stress, Lumbago, Cervical-brachial neuralgia, Cervical, Scapulohumeral periarthritis, Epicondylitis, Nausea, Carpal tunnel, Hip arthrosis, Patellar chondritis, Menstrual pain, Intense menstrual pain, Acute pain analgesic Tens, Chronic pain analgesic Tens, Modulated Tens, Deep effusion, Trapezialgia, Hip pain, Knee pain, Ankle pain
Tens antal. anti-accommodation, Fracture pain, Chronic pain, Rib fracture, Algodystrophy, Finger pain, Periostitis, Cervical rhizopathy, Phantom limb 1-2, Spinal compression
Mens (MCR)

MENS currents use currents whose intensity is between 10 and 500 µA (microamperes, or one millionth of an ampere).
Normally, MENS therapy involves two distinct phases, the first of which aims to reduce the painful sensation perceived by the patient, while the second phase promotes protein and ATP synthesis, accelerating tissue repair processes.

Epicondylitis, Scapulo-humeral periarthritis, Contractures, Muscle strain, Muscle tear, Muscle energy restoration, Contusion, Rheumatoid arthritis, Edema, Herpes zoster, Hematoma, Ischemic skin ulcer, Sciatica, Femoral neuralgia, Lumbago, Herniated disc and lumbar spondylosis, Brachial neuralgia, Stiff neck, Migraine, Neck pain "Whiplash", Cervical spondylosis, Shoulder sprain, Carpal tunnel syndrome, Hand arthritis, Finger fracture, Knee sprain, Patellar tendon inflammation, Knee osteoarthritis, Ankle sprain, Achilles tendon inflammation, Breast microlifting effect, Décolleté microlifting effect, Facial microlifting effect, Facial skin elasticity
Interferential

This particular type of current is called interferential because it creates an interference zone inside the tissues at the point where the fields cross. The interferential current is a sinusoidal alternating current at medium frequency (2500 Hz – 4000 Hz – 10000 Hz), modulated in amplitude, characterized by a high capacity for tissue penetration and excellent tolerability even by particularly sensitive patients.

Constant (for painful tendon and muscle pathologies), Sweep 80 – 100 Hz (for painful tendon and muscle pathologies) in the acute phase, Sweep 5 – 100 Hz (for painful tendon and muscle pathologies in the acute phase and in the presence of inflammation), Sweep 5 – 20 Hz (painful manifestations where reabsorption of edema is required (pump effect), Multi freq (reabsorption of edema in the presence of acute pain), Sweep 5 – 50 Hz (for muscle pathologies with the need for reabsorption of edema), Sweep 50 – 100 Hz (acute and chronic muscle pain), LP (used as an alternative to diadynamic LP), CP (used as an alternative to diadynamic LP), COST, LP, CP (Association of previous programs), AMF (Suitable for large areas of pain), Degenerative arthrosis of the knee, Acromial bursitis, Myotensive headache, Cervical Acute brachialgia, Coxarthrosis, Knee sprain, Acute neck pain, Acute back pain, Epicondylitis, Chronic lumbago, Scapulo-humeral periarthritis, Contractures, Shoulder sprain, Ankle sprain

Kotz

The Kotz current is used in the medical field because it produces good muscle recruitment and carries out a deeper action than other excitomotor currents.
The effect of the Kotz current is in fact achieved in the deeper layers of the muscles because the skin offers less resistance to this type of current.

Residual hypotrophy from suffering L5, Hypotrophy of the anterior rectus quadriceps, Post-traumatic hypotrophy of the hamstrings, Post-traumatic hypotrophy of the deltoid, Hypotrophy of the triceps, Hypotrophy of the vastus medialis, Chronic low back pain, Muscle strengthening after meniscopathy, Vertebral osteoporosis, Flat foot, Lumbar vertebral fracture, Quadriceps strength, Advanced muscle reactivation, hypokinetic syndrome, Metatarsalgia, Reactivation of the gluteus medius, Muscle strengthening of the serratus, Isometric strengthening of the quadriceps, Muscle strengthening of the periphery, Warming up, Scoliosis, Muscle toning, Thoracic hyperkyphosis, Muscle hypertrophy, Hypotrophy of the dorsal paravertebral muscles, Muscle training, Inveterate coxarthrosis, gluteal hypotrophy, Cooling down, Gluteal deficit from suffering, Colles fracture – flexor reactivation

Denervated Muscles

The stimulation of a denervated muscle differs from that of a healthy muscle in that the activation of the muscle fibres requires particular currents.
In the presence of a traumatic lesion of the peripheral nerves, the measurement of chronaxias allows to establish whether the denervation is poor, partial or total.

1a – Rectangular Impulse Shape 1
1b – Rectangular Impulse Shape 2
1c – Rectangular Impulse Shape 3
2a – Triangular Impulse Shape 1
2b – Triangular Impulse Shape 2
2c – Triangular Impulse Shape 3
3a – Trapezoidal pulse shape 1
3b – Trapezoidal pulse shape 2
3c – Trapezoidal Impulse Shape 3

Ionophoresis

The iontophoresis program works by transporting pharmacological substances into the tissues thanks to a unidirectional continuous electric current.
The ions of the medicinal substance are transported into the body through areas of the skin that offer low resistance to the current, thus reaching the cell membranes.
Aesthetics

The Genesy 3000 has a range of programs designed for body care and beauty: there are numerous specific treatments such as drainage, modelling, lipolysis, facial toning, anti-cellulite actions that can be applied individually or in combination with each other.
The effect of the stimulation is in fact enhanced if you combine multiple treatments together in each session: each phase of the treatment in fact acts with different and specific methods (for example: superficial massage-drainage-deep massage-anti-cellulite action, toning) which, acting in synergy with each other, give you the best and most long-lasting results.

Bio-pulse drainage, *Lipolysis 1-2, *Relaxing massage, *Toning massage 1-2, *Energy massage 1-2, *Connective tissue massage 1-2, Postpartum drainage, Postpartum lipolysis, Postpartum firming, Breast firming, Breast shaping, *Swollen arms, *Facial capillarization, *Facial lifting effect, *Arterial insufficiency, *Venous insufficiency, *Definition 1-2, *Line 1-2, *Vascularization 1-2

(* = Program available for both men and women)

Sport

The Genesy 3000 offers a range of sports training programs suitable for meeting the preparation needs of high-level athletes in the main sports disciplines.

*Warm-up, *Pre-race warm-up, *Active recovery, *Maximum strength 1-2, *Resistance strength 1-2, *Explosive strength 1-2, *Aerobic resistance 1-2, *Reactivity, *Post-race recovery, *Decontracting, *Hypertrophy, *Dynamic work 1-2

(* = Program available for both men and women)

Fitness

*Firming, *Bio-pulse Firming, Shaping, *Bio-pulse Shaping, *Toning, *Mass Increase, *Body Sculpting, *Definition, *Jogging, *Anaerobic, *Muscle Initiation, *Aerobic, *Cramp Prevention
Note: * indicates that both the Men's and Women's programs are present

(* = Program available for both men and women)

TECHNICAL FEATURES: Channels: 4 independent CHANNELS (8 electrodes)
Frequency: 0.3 – 150 Hz
Power: 120 mA per channel
Pulse width: 45 - 450 µs
Waveform: Compensated symmetric biphasic square wave
Power supply: Power supply 18V – 3.3A
Battery: 12V, 2000mAh
Conformity: It complies with the ISO 9001, EN 46001 Standard for electromedical products. MDD (Medical Device Directive) certificates

EQUIPMENT:

1 Bag, 1 Stimulator, 4 Cables for connection to the electrodes, 1 Mains charger., 4 Self-adhesive electrodes 50 × 50, 4 Self-adhesive electrodes 50 × 90, 1 Operating manual

3 years warranty! By purchasing this product, Globus will give you the opportunity to activate 1 additional year of warranty, through registration after purchase (2 + 1 years).

Dedicated Assistance Service. Globus offers a direct and immediate Assistance Service to solve any problem.

EAN CODE 8032625825418
ART. CODE G1367

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

TOORX PROFESSIONAL LINE

Discover the new Toorx Professional Weight Stack line

Globus Genesy 3000 elettrostimolatore
Globus

Globus Genesy 3000 electrostimulator

€979,00 EUR €999,00

Product Features:

The Globus Genesy 3000 represents the flagship of the new Globus professional range as it concentrates the best technologies and functions that Globus has developed in recent years.

This second-generation professional electrostimulator is in fact the result of a new hardware and software project that has implemented the potential for use in the medical, rehabilitation and physiotherapy fields.

The unit, characterised by larger dimensions and an ergonomic design, thanks to its mains and battery operation can be used both as a fixed station and as a portable unit.

The Genesy 3000 is the most equipped stimulator for the treatment of pain, to promote tissue healing and to treat neuromuscular dysfunctions.
The System is designed to allow a more effective and rapid re-athleticization of injured athletes and to reduce, at the same time, the possibility of new injuries. The programs are specifically designed both to resolve the acute post-traumatic phase and to recover athletes who should undergo reconstructive surgery.

This machine also has a set of specific programs for athletic preparation in the most important sports disciplines.
The facilities are completed by a full range of body care treatments with purely aesthetic purposes.

8 DIFFERENT TYPES OF CURRENT

The Genesy 3000 in particular stands out for its ability to deliver all the main medical currents:


-EMS currents (Electro Muscle Stimulation)
-TENS currents (Trans Cutaneus Nerve Stimulation)
-MENS currents (Micro Current Stimulation)
-Kotz currents with sine wave
-Interferential Currents
-Triangular and Trapezoidal wave currents for the Denervated M.
-Direct Current for Ionophoresis

9 APPLICATION AREAS

The technologies used are the most advanced and allow for extremely easy and safe use of the stimulator in any therapeutic situation.


-Functional re-education (EMS and MENS),
-Pain Therapy (TENS and MENS),
-Endorphin Pain Therapy (TENS and MENS)
-Diagnosis and Treatment of Denervated Muscle Paralysis
-Rehabilitation treatments (Kotz and Interferential)
-Deep Pharmacological Treatment (Ionophoresis)
-High Level Sports Training (EMS)
-Fitness Preparation (EMS)
-Aesthetic Treatments (EMS, MENS).

STRENGTHS

Considerable attention has been paid to making the use of the machine more intuitive and user-friendly.

GENESY SERIES FUNCTIONS


EASY PROGRAM: allows for faster programming
MY TRAINER: view all the images of the electrode placement directly on the display
STIM FIT: allows you to modify the contraction parameters during stimulation
FAST MENU: makes navigation faster
STIM LOCK: allows the therapist to have the patient use only the programs that have been prescribed to him
WORK TIME: displays the actual machine usage times by all users
MAINS & BATTERY OPERATION.
NEW DOUBLE POWER BATTERY

SPECIAL FUNCTIONS


BACKLIT GRAPHIC DISPLAY
DUAL STIM 2+2: possibility of running two different programs at the same time.
AUTO STIM: the only electrostimulator that allows you to run a program automatically without having to manually adjust the intensity.
SYNCROSTIM: By pressing a single button, you can increase the intensity of the 4 channels simultaneously.
MULTI-USER: allows you to share the stimulator between multiple users, keeping their respective settings, preferences and programs memorized.
MEMO FUNCTION: allows you to create a library of customized programs.
LAST 10: stores the last programs performed. In this way they are available for quick and easy execution.

PROGRAMS

Rehab

Rehabilitation programs use EMS currents to restore normal muscle efficiency in post-injury recovery treatments.
Muscle stimulation is also a useful tool in some situations where normal neuromuscular function is compromised.

Atrophy Recovery, Point Finder, Muscle Building, Strengthening, Mobilization, Agonist/Antagonist, Cruciate Ligament Stretching, Achilles Tendon Stretching, Upper Ligament Ligament Stretching, Upper Limb Hemiplegia, Lower Limb Hemiplegia, Bladder Instability, Mixed Incontinence, Stress Incontinence, Paraplegia (injury prevention), Upper Limb Spasticity, Lower Limb Spasticity, Hip Prosthesis
Tens

Transcutaneous Electrical Nerve Stimulation. Transcutaneous electrical nerve stimulation (TENS) is a pain-relieving stimulation that is performed with impulses that reach the peripheral nervous system through electrodes positioned on the area to be treated. TENS stimulation is performed with symmetrical biphasic impulses and with frequencies that can vary from 8 to 200 Hz.

Endorphinic Tens, Hematomas, Contractures, Sciatica, Anti-stress, Lumbago, Cervical-brachial neuralgia, Cervical, Scapulohumeral periarthritis, Epicondylitis, Nausea, Carpal tunnel, Hip arthrosis, Patellar chondritis, Menstrual pain, Intense menstrual pain, Acute pain analgesic Tens, Chronic pain analgesic Tens, Modulated Tens, Deep effusion, Trapezialgia, Hip pain, Knee pain, Ankle pain
Tens antal. anti-accommodation, Fracture pain, Chronic pain, Rib fracture, Algodystrophy, Finger pain, Periostitis, Cervical rhizopathy, Phantom limb 1-2, Spinal compression
Mens (MCR)

MENS currents use currents whose intensity is between 10 and 500 µA (microamperes, or one millionth of an ampere).
Normally, MENS therapy involves two distinct phases, the first of which aims to reduce the painful sensation perceived by the patient, while the second phase promotes protein and ATP synthesis, accelerating tissue repair processes.

Epicondylitis, Scapulo-humeral periarthritis, Contractures, Muscle strain, Muscle tear, Muscle energy restoration, Contusion, Rheumatoid arthritis, Edema, Herpes zoster, Hematoma, Ischemic skin ulcer, Sciatica, Femoral neuralgia, Lumbago, Herniated disc and lumbar spondylosis, Brachial neuralgia, Stiff neck, Migraine, Neck pain "Whiplash", Cervical spondylosis, Shoulder sprain, Carpal tunnel syndrome, Hand arthritis, Finger fracture, Knee sprain, Patellar tendon inflammation, Knee osteoarthritis, Ankle sprain, Achilles tendon inflammation, Breast microlifting effect, Décolleté microlifting effect, Facial microlifting effect, Facial skin elasticity
Interferential

This particular type of current is called interferential because it creates an interference zone inside the tissues at the point where the fields cross. The interferential current is a sinusoidal alternating current at medium frequency (2500 Hz – 4000 Hz – 10000 Hz), modulated in amplitude, characterized by a high capacity for tissue penetration and excellent tolerability even by particularly sensitive patients.

Constant (for painful tendon and muscle pathologies), Sweep 80 – 100 Hz (for painful tendon and muscle pathologies) in the acute phase, Sweep 5 – 100 Hz (for painful tendon and muscle pathologies in the acute phase and in the presence of inflammation), Sweep 5 – 20 Hz (painful manifestations where reabsorption of edema is required (pump effect), Multi freq (reabsorption of edema in the presence of acute pain), Sweep 5 – 50 Hz (for muscle pathologies with the need for reabsorption of edema), Sweep 50 – 100 Hz (acute and chronic muscle pain), LP (used as an alternative to diadynamic LP), CP (used as an alternative to diadynamic LP), COST, LP, CP (Association of previous programs), AMF (Suitable for large areas of pain), Degenerative arthrosis of the knee, Acromial bursitis, Myotensive headache, Cervical Acute brachialgia, Coxarthrosis, Knee sprain, Acute neck pain, Acute back pain, Epicondylitis, Chronic lumbago, Scapulo-humeral periarthritis, Contractures, Shoulder sprain, Ankle sprain

Kotz

The Kotz current is used in the medical field because it produces good muscle recruitment and carries out a deeper action than other excitomotor currents.
The effect of the Kotz current is in fact achieved in the deeper layers of the muscles because the skin offers less resistance to this type of current.

Residual hypotrophy from suffering L5, Hypotrophy of the anterior rectus quadriceps, Post-traumatic hypotrophy of the hamstrings, Post-traumatic hypotrophy of the deltoid, Hypotrophy of the triceps, Hypotrophy of the vastus medialis, Chronic low back pain, Muscle strengthening after meniscopathy, Vertebral osteoporosis, Flat foot, Lumbar vertebral fracture, Quadriceps strength, Advanced muscle reactivation, hypokinetic syndrome, Metatarsalgia, Reactivation of the gluteus medius, Muscle strengthening of the serratus, Isometric strengthening of the quadriceps, Muscle strengthening of the periphery, Warming up, Scoliosis, Muscle toning, Thoracic hyperkyphosis, Muscle hypertrophy, Hypotrophy of the dorsal paravertebral muscles, Muscle training, Inveterate coxarthrosis, gluteal hypotrophy, Cooling down, Gluteal deficit from suffering, Colles fracture – flexor reactivation

Denervated Muscles

The stimulation of a denervated muscle differs from that of a healthy muscle in that the activation of the muscle fibres requires particular currents.
In the presence of a traumatic lesion of the peripheral nerves, the measurement of chronaxias allows to establish whether the denervation is poor, partial or total.

1a – Rectangular Impulse Shape 1
1b – Rectangular Impulse Shape 2
1c – Rectangular Impulse Shape 3
2a – Triangular Impulse Shape 1
2b – Triangular Impulse Shape 2
2c – Triangular Impulse Shape 3
3a – Trapezoidal pulse shape 1
3b – Trapezoidal pulse shape 2
3c – Trapezoidal Impulse Shape 3

Ionophoresis

The iontophoresis program works by transporting pharmacological substances into the tissues thanks to a unidirectional continuous electric current.
The ions of the medicinal substance are transported into the body through areas of the skin that offer low resistance to the current, thus reaching the cell membranes.
Aesthetics

The Genesy 3000 has a range of programs designed for body care and beauty: there are numerous specific treatments such as drainage, modelling, lipolysis, facial toning, anti-cellulite actions that can be applied individually or in combination with each other.
The effect of the stimulation is in fact enhanced if you combine multiple treatments together in each session: each phase of the treatment in fact acts with different and specific methods (for example: superficial massage-drainage-deep massage-anti-cellulite action, toning) which, acting in synergy with each other, give you the best and most long-lasting results.

Bio-pulse drainage, *Lipolysis 1-2, *Relaxing massage, *Toning massage 1-2, *Energy massage 1-2, *Connective tissue massage 1-2, Postpartum drainage, Postpartum lipolysis, Postpartum firming, Breast firming, Breast shaping, *Swollen arms, *Facial capillarization, *Facial lifting effect, *Arterial insufficiency, *Venous insufficiency, *Definition 1-2, *Line 1-2, *Vascularization 1-2

(* = Program available for both men and women)

Sport

The Genesy 3000 offers a range of sports training programs suitable for meeting the preparation needs of high-level athletes in the main sports disciplines.

*Warm-up, *Pre-race warm-up, *Active recovery, *Maximum strength 1-2, *Resistance strength 1-2, *Explosive strength 1-2, *Aerobic resistance 1-2, *Reactivity, *Post-race recovery, *Decontracting, *Hypertrophy, *Dynamic work 1-2

(* = Program available for both men and women)

Fitness

*Firming, *Bio-pulse Firming, Shaping, *Bio-pulse Shaping, *Toning, *Mass Increase, *Body Sculpting, *Definition, *Jogging, *Anaerobic, *Muscle Initiation, *Aerobic, *Cramp Prevention
Note: * indicates that both the Men's and Women's programs are present

(* = Program available for both men and women)

TECHNICAL FEATURES: Channels: 4 independent CHANNELS (8 electrodes)
Frequency: 0.3 – 150 Hz
Power: 120 mA per channel
Pulse width: 45 - 450 µs
Waveform: Compensated symmetric biphasic square wave
Power supply: Power supply 18V – 3.3A
Battery: 12V, 2000mAh
Conformity: It complies with the ISO 9001, EN 46001 Standard for electromedical products. MDD (Medical Device Directive) certificates

EQUIPMENT:

1 Bag, 1 Stimulator, 4 Cables for connection to the electrodes, 1 Mains charger., 4 Self-adhesive electrodes 50 × 50, 4 Self-adhesive electrodes 50 × 90, 1 Operating manual

3 years warranty! By purchasing this product, Globus will give you the opportunity to activate 1 additional year of warranty, through registration after purchase (2 + 1 years).

Dedicated Assistance Service. Globus offers a direct and immediate Assistance Service to solve any problem.

EAN CODE 8032625825418
ART. CODE G1367

View product